Fix PF electrical accounting for Ohmic heating - #4664
grmtrkngtn wants to merge 1 commit into
Conversation
Codecov Report✅ All modified and coverable lines are covered by tests. Additional details and impacted files@@ Coverage Diff @@
## main #4664 +/- ##
=======================================
Coverage 49.73% 49.73%
=======================================
Files 151 151
Lines 30297 30297
=======================================
Hits 15069 15069
Misses 15228 15228 ☔ View full report in Codecov by Harness. 🚀 New features to boost your workflow:
|
| 1.0e0 / self.data.pf_coil.etapsu - 1.0e0 | ||
| # PF wall-plug power required for ohmic heating (MW) | ||
| wall_plug_ohmicmw = ( | ||
| self.data.physics.p_plasma_ohmic_mw / self.data.pf_coil.etapsu |
There was a problem hiding this comment.
I can be very misinformed, but why does electrical losses in the PF coil depend linearly on the plasma resistivity?
There was a problem hiding this comment.
This term is intended to represent the power-supply loss associated with transferring the ohmic heating power to the plasma, rather than a resistive loss in the PF coils themselves.
Since the plasma ohmic heating is
P_ohmic = V_loop * I_p = I_p^2 * R_plasma
and therefore depends on the plasma resistance, a fixed power-supply efficiency gives a loss
P_ohmic * (1/η_psu − 1)
The PF coil/busbar losses are accounted for separately in pfpowermw.
There was a problem hiding this comment.
Looking here for some reason we only say there is resistive heating power if their is inductive current drive. What happens in the ST case when there is no inductive flattop?
chris-ashe
left a comment
There was a problem hiding this comment.
The logic makes sense but I think we need to sort out the proper order for the calculations and how we treat when the source of the ohmic heating power comes from. As at the moment it only works inductive machines
Description
The PF electrical demand previously included only the power-supply loss associated with ohmic heating, while the ohmic power itself was still added to the plasma thermal balance. This caused the whole-plant power balance to gain an amount exactly equal to p_plasma_ohmic_mw.
The fix accounts for the full wall-plug power required to supply ohmic heating, while only the PF supply losses contribute to secondary heat.
See #4419
************************ Power balance for power plant *************************
IN
Fusion power (MW) (p_fusion_total_mw) 1.67020126538901764e+03 OP
Energy multiplication in blanket and shield (MW) (p_blkt_multiplication_mw) 2.47869045393520537e+02 OP
TOTAL (MW) (p_nuclear_total_mw) 1.91807031078253817e+03 OP
OUT
Net electric (MW) (p_plant_electric_net_mw) 3.50000000004303502e+02 OP
Heat rejected by main power conversion circuit (MW) (p_turbine_loss_mw) 1.36108730187131050e+03 OP
Heat rejected by other circuits (secondary heat) (MW) (p_plant_secondary_heat_mw) 2.06983008906924198e+02 OP
TOTAL (MW) (p_plant_out_mw) 1.91807031078253817e+03 OP
Power plant overall imbalance (MW) (p_plant_imbalance_mw) 0.00000000000000000e+00 OP
We can see the power imabalance is correct now